Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Rev. colomb. ortop. traumatol ; 35(3): 253-260, 2021. ilus.
Article in Spanish | LILACS, COLNAL | ID: biblio-1378687

ABSTRACT

Introducción El objetivo de este estudio fue determinar si existen diferencias en el ángulo crítico del hombro medido por resonancia magnética en pacientes con ruptura de manguito rotador en comparación con pacientes sanos, así mismo, determinar la fiabilidad intraobservador del ángulo crítico del hombro. Se midieron diferentes variables en la resonancia magnética las cuales incluían: la extensión lateral del acromion, la altura acromial, la versión de la glenoides, el ángulo lateral del acromion y la inclinación glenoidea. Materiales y métodos Se evaluaron dos grupos de pacientes, el grupo control con un total de 16 pacientes y el grupo con ruptura de manguito rotador con 15 pacientes. Se midió en resonancia magnética el ángulo crítico del hombro, inclinación glenoidea, versión de la glenoides, altura acromial, extensión lateral del acromion y el ángulo lateral del acromion. Se utilizó la prueba T de student para comparación de medias y el coeficiente de correlación de Pearson para la asociación entre variables. Así mismo se utilizó el coeficiente de correlación intraclase para la valoración de la fiabilidad intraobservador. Resultados Se obtuvo un resultado de 0.961 en el coeficiente de correlación intraclase para la fiabilidad intraobservador del ángulo crítico del hombro. En la comparación de medias para el ángulo crítico del hombro entre el grupo control y el grupo con ruptura de manguito rotador se obtuvo un resultado de 32.3°(3.6) vs 35.01°(2.4) con una diferencia estadisticamente significativa(p=0.02). De igual manera se obtuvieron diferencias significativas en la inclinación glenoidea y la versión de la glenoides en ambos grupos (81.56°DE 4.04 vs 77.11° DE 3.84; p=0.004) y (-4.47° DE 4.56 vs -1.58°DE 3.94; p=0.04). Discusión Existen diferencias significativas en la medición del ángulo crítico del hombro medido por resonancia magnética en pacientes sanos y pacientes con ruptura de manguito rotador.


Background The purpose of this study was to determine if there is a difference between the critical shoulder angle measured by MRI in patients with rotator cuff tear and healthy patients, also to evaluate the intraobserver reliability in this measure. Other variables were included as well, lateral acromial extension, acromial height, glenoid version, glenoid inclination and lateral acromial angle. Materials and methods Two groups were evaluated, the control group consisted in a total of 16 patients and the group with rotator cuff tear consisted of 15 patients. The critical shoulder angle, glenoid inclination, glenoid version, acromial height, lateral acromial extension and lateral acromial angle were measured on MRI. A student T test was used for comparison of means between both groups, Pearson correlation coefficient was used for evaluating the association between variables. The intraobserver reliability was evaluated using the intraclass correlation coefficient. Results A result of 0.961 was obtained for the intraobserver reliability using the intraclass correlation coefficient for the critical shoulder angle. For the comparison of means of the critical shoulder angle in the control group and the rotator cuff tear group a result of 32.3° (3.6) vs. 35.01° (2.4) was obtained with a statistically significant difference of p=0.02. Likewise, statistically significant differences were obtained in the glenoid inclination and glenoid version in both groups (81.56° SD 4.04 vs 77.11° SD 3.84; p=0.004) and (−4.47° SD 4.56 vs −1.58° SD 3.94; p=0.04). Discussion Critical shoulder angle measured by MRI is statistically significant different in control group and in rotator cuff tear group.


Subject(s)
Humans , Rotator Cuff , Rupture , Acromion , Glenoid Cavity
2.
Int. j. morphol ; 33(4): 1386-1392, Dec. 2015. ilus
Article in English | LILACS | ID: lil-772327

ABSTRACT

The abundant vascular structures that surround the shoulder joint are complex and variable, complicating arthroscopy approaches. The aim of this study is to determine safe and risky areas around standard posterior and standard anterior portals, and accounting for the distribution of neurovascular structures of small and medium diameters that can lead to intra-articular bleeding during surgery. The standard posterior portal, and standard anterior portal were placed as described in the literature, and punch dissection was performed 2.5 cm around the trocar in situ. The arrangement of each identified structure was photographically documented and digitalized for each anatomic plane; the distance to the trocar and the diameter of each structure were measured. Based on each digitalized anatomic plane, safe and risky tissue areas were determined, and a clock face coordinate system was used to represent these areas. The safe area around the standard posterior portal was located between 11 and 1 o´clock for the left shoulder and 11 and 2 o´clock for the right shoulder. For the standard anterior portal, the safe area was located between 2 and 3 o´clock for the left shoulder and between 9 and 12 o´clock for the right shoulder. However, we did document a risk of injuring the cephalic vein 5 times, the axillary artery 3 times and the deltoid branch of the thoracoacromial artery once. This study reports quantitatively the total number of small diameter structures present in the two shoulder arthroscopic portals evaluated. The safe areas proposed in this study must be evaluated to propose new access points for performing arthroscopic procedures on the shoulder.


Las abundantes estructuras vasculares que rodean la articulación del hombro son complejas y variables, y dificultan los abordajes artroscópicos. El objetivo del estudio fue determinar áreas seguras y en riesgo en relación al portal posterior estándar y el portal anterior estándar y cuantificar la distribución de estructuras de diámetro pequeño e intermedio que puedan conducir a sangrado intraarticular durante la cirugía. El portal posterior estándar y el portal anterior estándar fueron colocados según su descripción en la literatura y fueron realizadas disecciones en sacabocado de 2,5 cm alrededor del trocar in situ. La disposición de cada estructura identificada fue documentada fotográficamente y digitalizada para cada plano anatómico. La distancia hacia el trocar y el diámetro de cada estructura fueron medidos. Basado en cada plano anatómico digitalizado, áreas de seguridad y riesgo tisular fueron determinadas y un sistema de coordenadas de manecillas de reloj fue utilizado para representar estas áreas. El área segura alrededor del portal posterior estándar fue localizada entre las 11 y las 1 en el sistema de las manecillas del reloj para hombros izquierdos y entre las 11 y las 2 para hombros derechos. Para el portal anterior estándar, el área segura fue localizada entre las 2 y 3 horas para hombros izquierdos y entre las 9 y 12 horas para hombros derechos. Aun así, se documentó el riesgo de lesionar la vena cefálica en 5 ocasiones, la arteria axilar en 3 ocasiones y la rama deltoidea de la arteria toracroacromial en una ocasión. Este estudio reporta cuantitativamente el número total de estructuras de pequeño diámetro presentes en los dos portales artroscopicos evaluados. Las áreas seguras propuestas en este estudio deben ser evaluadas para proponer nuevos puntos de acceso para la realización de procedimientos artroscopicos en el hombro.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Arthroscopy/methods , Shoulder/anatomy & histology , Cadaver , Cross-Sectional Studies , Patient Positioning
SELECTION OF CITATIONS
SEARCH DETAIL